Body Roundness Index (BRI)

ورودی‌های بالینی بیمار

حداقل ۴۰ — حداکثر ۲۰۰ • واحد: cm

حداقل ۱۰۰ — حداکثر ۲۵۰ • واحد: cm

پنل نتیجه و تصمیم بالینی
در انتظار ورودی‌ها
body roundness index
—index
آماده برای ارزیابی

پارامترهای بالینی بیمار را در فرم روبرو وارد کنید و روی «محاسبه» کلیک نمایید تا نمره، طبقه خطر و اقدامات فوری نمایش داده شوند.

طبقات خطر و بازه‌های امتیاز:
  • Low BRI0–3.41
  • Below Average BRI3.41–4.45
  • Average BRI4.45–5.46
  • Above Average BRI5.46–6.91
Direct Clinical Answer

The Body Roundness Index (BRI) calculates estimating basal energy expenditure, macro- and micronutrient requirements, and fluid balance. Key inputs include waist circumference. Scores guide tailoring enteral or parenteral nutrition formulas, electrolyte supplementation, and metabolic monitoring. This standardized assessment improves clinical decision safety and bedside patient management.

Clinical Guidelines & Evidence

Estimates % body fat and % visceral adipose tissue (VAT) based on waist circumference and height. BRI provides a geometric assessment of body shape and correlates with mortality risk and cardiometabolic health outcomes.

Clinical Indication

The Body Roundness Index (BRI) is indicated for bedside clinical practice to support Estimates % body fat and % visceral adipose tissue (VAT) based on waist circumference and height. BRI provides a geometric assessment of body shape and correlates with mortality risk and cardiometabolic health outcomes.. It assists healthcare providers in standardizing clinical assessment and therapeutic decision-making.

Target Population

Target population comprises Hospitalized patients with acute or chronic malnutrition, indicated for total parenteral nutrition (TPN) or enteral tube feeding. Clinical application is indicated across Clinical nutrition teams, surgical recovery wards, intensive care, and metabolic clinics.

Limitations & Contraindications

Anasarca, severe peripheral edema, or ascites artificially inflates body weight and distorts caloric calculations.

Clinical Pearls & Action Plan

Cautious progressive refeeding with daily surveillance of serum phosphate, potassium, and magnesium prevents refeeding syndrome. Guideline pearl: BRI is a relatively new index and may require further validation in diverse populations.

Formula & Variables:

BRI = 364.2 - 365.5 × √(1 - [(WC/2π) / (0.5 × H)]²) where WC is waist circumference and H is height in the same units

Input Parameters

NameTypeRequiredDescription
waist_circumferencefloatYesWaist circumference measured at the level of the umbilicus (navel) in centimeters(cm)
heightfloatYesHeight in centimeters(cm)

Score Interpretation & Guidance

RangeStageDescription
0–3.41Low BRILow body roundness
3.41–4.45Below Average BRIBelow average body roundness
4.45–5.46Average BRIAverage body roundness (reference)
5.46–6.91Above Average BRIAbove average body roundness
6.91–20High BRIHigh body roundness

Evidence-Based References (EBM)

  • Thomas DM, Bredlau C, Bosy-Westphal A, et al. Relationships between body roundness with body fat and visceral adipose tissue emerging from a new geometrical model. Obesity (Silver Spring). 2013 Nov;21(11):2264-71. doi: 10.1002/oby.20408.DOI: 10.1002/oby.20408
  • Zhang X, Ma N, Lin Q, et al. Body Roundness Index and All-Cause Mortality Among US Adults. JAMA Netw Open. 2024 Jun 3;7(6):e2415051. doi: 10.1001/jamanetworkopen.2024.15051.DOI: 10.1001/jamanetworkopen.2024.15051
  • Chang Y, Guo X, Chen Y, et al. A body shape index and body roundness index: two new body indices to identify diabetes mellitus among rural populations in northeast China. BMC Public Health. 2015 Aug 19;15:794. doi: 10.1186/s12889-015-2150-2.DOI: 10.1186/s12889-015-2150-2

Related calculators