Corrected Count Increment (CCI) for Platelet Transfusion
ورودیهای بالینی بیمار
حداقل ۰ — حداکثر ۵۰۰۰۰۰ • واحد: platelets/μL
حداقل ۰ — حداکثر ۵۰۰۰۰۰ • واحد: platelets/μL
حداقل ۴۸ — حداکثر ۹۰ • واحد: inches
حداقل ۰.۵ — حداکثر ۶۲۰ • واحد: lbs
حداقل ۰.۵ — حداکثر ۵۰۰ • واحد: ×10¹¹ platelets
پارامترهای بالینی بیمار را در فرم روبرو وارد کنید و روی «محاسبه» کلیک نمایید تا نمره، طبقه خطر و اقدامات فوری نمایش داده شوند.
- Successful Transfusion≥ 7500
- Poor Response≤ 7500
- Successful Transfusion≥ 4800
- Poor Response≤ 4800
The Corrected Count Increment (CCI) for Platelet Transfusion calculator is designed for bedside assessing adequacy of response to platelet transfusion by measuring the expected increase in platelets adjusted for patient size and platelet dose in clinical practice. The resulting score directly guides clinician decision-making regarding.
Clinical Guidelines & Evidence
Assesses adequacy of response to platelet transfusion by measuring the expected increase in platelets adjusted for patient size and platelet dose
Clinical Indication
The Corrected Count Increment (CCI) for Platelet Transfusion is indicated for bedside clinical practice to support Assesses adequacy of response to platelet transfusion by measuring the expected increase in platelets adjusted for patient size and platelet dose. It assists healthcare providers in standardizing clinical assessment and therapeutic decision-making.
Target Population
Target population comprises Patients presenting with coagulopathy, thrombocytopenia, venous thromboembolism (DVT/PE), or hematologic neoplasms. Clinical application is indicated across Hematology-oncology services, bone marrow transplant units, anticoagulation clinics, and acute medical wards.
Limitations & Contraindications
Severe thrombocytopenia with concomitant microvascular thrombosis (TTP, HIT, DIC) represents a medical emergency requiring rapid intervention.
Clinical Pearls & Action Plan
Detailed history of heparin exposure, platelet count kinetics, and comprehensive coagulation profiles are vital in consumptive coagulopathies.
CCI = (Post-transfusion count - Pre-transfusion count) × BSA / Platelet dose, where BSA = sqrt((height_cm × weight_kg) / 3600)
Input Parameters
| Name | Type | Required | Description |
|---|---|---|---|
| pre_transfusion_count | integer | Yes | Pre-transfusion platelet count(platelets/μL) |
| post_transfusion_count | integer | Yes | Post-transfusion platelet count(platelets/μL) |
| time_after_transfusion | string | Yes | Time after transfusion when post-transfusion count was measured |
| patient_height | float | Yes | Patient height(inches) |
| patient_weight | float | Yes | Patient weight(lbs) |
| platelet_unit_content | float | Yes | Total platelet content in transfused units(×10¹¹ platelets) |
Score Interpretation & Guidance
| Range | Stage | Description |
|---|---|---|
| ≥ 7500 | Successful Transfusion | Good platelet response at 1 hour |
| ≤ 7500 | Poor Response | Inadequate platelet response at 1 hour |
| ≥ 4800 | Successful Transfusion | Good platelet response at 20 hours |
| ≤ 4800 | Poor Response | Inadequate platelet response at 20 hours |
Evidence-Based References (EBM)
- Davis KB, Slichter SJ, Corash L. Corrected count increment and percent platelet recovery as measures of posttransfusion platelet response: problems and a solution. Transfusion. 1999;39(6):586-92.
- Bishop JF, Matthews JP, McGrath K, Yuen K, Wolf MM, Szer J. Factors influencing 20-hour increments after platelet transfusion. Transfusion. 1991;31(5):392-6.
- Slichter SJ, Davis K, Enright H, et al. Factors affecting posttransfusion platelet increments, platelet refractoriness, and platelet transfusion intervals in thrombocytopenic patients. Blood. 2005;105(10):4106-14.