ADAPT Protocol for Cardiac Event Risk

ورودی‌های بالینی بیمار

پنل نتیجه و تصمیم بالینی
در انتظار ورودی‌ها
adapt risk level
—امتیاز
آماده برای ارزیابی

پارامترهای بالینی بیمار را در فرم روبرو وارد کنید و روی «محاسبه» کلیک نمایید تا نمره، طبقه خطر و اقدامات فوری نمایش داده شوند.

طبقات خطر و بازه‌های امتیاز:
  • Low Risk0–0
  • High Risk1–7
Direct Clinical Answer

The ADAPT Protocol for Cardiac Event Risk calculates assessing chest pain patients at 2 hours for risk of cardiac event. Key inputs include abnormal troponin. Scores guide determining acute hospital admission, emergency department discharge safety, or intensive care transfer. This standardized assessment improves clinical decision safety and bedside patient management.

Clinical Guidelines & Evidence

Assesses chest pain patients at 2 hours for risk of cardiac event. Uses elevated troponin, ischemic ECG changes, and TIMI risk factors to stratify patients into low and high risk categories for major adverse cardiac events at 30 days.

Clinical Indication

The ADAPT Protocol for Cardiac Event Risk is indicated for bedside clinical practice to support Assesses chest pain patients at 2 hours for risk of cardiac event. Uses elevated troponin, ischemic ECG changes, and TIMI risk factors to stratify patients into low and high risk categories for major adverse cardiac events at 30 days.. It assists healthcare providers in standardizing clinical assessment and therapeutic decision-making.

Target Population

Target population comprises Adult and pediatric patients presenting with acute undifferentiated clinical complaints, trauma, or unstable vital signs. Clinical application is indicated across Emergency triage, acute resuscitation bays, observation units, and emergency trauma centers.

Limitations & Contraindications

Score calculations must never delay immediate life-saving airway stabilization, vascular access, or emergent surgical consult. Clinical exclusion: Excludes patients with obvious ST-elevation MI, cardiogenic shock, or life-threatening arrhythmias.

Clinical Pearls & Action Plan

Adherence to core ABCDE resuscitation principles and bedside clinical gestalt must take absolute precedence over numerical decision tools. Guideline pearl: High-sensitivity troponin assays are recommended for optimal performance.

Formula & Variables:

ADAPT uses a binary decision tree approach: High risk if any of the following are present: abnormal troponin at 0 or 2 hours, ischemic changes on ECG, or any TIMI risk factors (age ≥65, ≥3 CAD risk factors, known CAD, aspirin use in past 7 days, severe angina). Low risk if none of these criteria are met.

Input Parameters

NameTypeRequiredDescription
abnormal_troponinstringYesAbnormal troponin at 0 or 2 hours
ischemic_changes_ecgstringYesIschemic changes on ECG
age_65_or_olderstringYesAge ≥65 years
three_or_more_cad_risk_factorsstringYes≥3 CAD risk factors (hypertension, hypercholesterolemia, diabetes, family history of coronary artery disease, or current smoker)
known_cadstringYesKnown CAD (stenosis ≥50%)
aspirin_use_past_7_daysstringYesAspirin use in past 7 days
severe_anginastringYesSevere angina (≥2 episodes in 24 hrs or persisting discomfort)

Score Interpretation & Guidance

RangeStageDescription
0–0Low RiskLow risk for major cardiac event
1–7High RiskHigh risk for major cardiac event

Evidence-Based References (EBM)

  • Than M, Flaws D, Sanders S, Doust J, Glasziou P, Kline J, Aldous S, Troughton R, Reid C, Parsonage WA, Frampton C, Greenslade JH, Deely JM, Hess E, Sadiq AB, Singleton R, Shopland R, Vercoe L, Woolhouse-Williams M, Ardagh M, Bossuyt P, Bannister L, Cullen L. Development and validation of the Emergency Department Assessment of Chest pain Score and 2 h accelerated diagnostic protocol. Emerg Med Australas. 2014 Feb;26(1):34-44. doi: 10.1111/1742-6723.12164.DOI: 10.1111/1742-6723.12164
  • Cullen L, Mueller C, Parsonage WA, Wildi K, Greenslade JH, Twerenbold R, Aldous S, Meller B, Tate JR, Reichlin T, Hammett CJ, Zellweger C, Ungerer JP, Rubini Gimenez M, Troughton R, Murray K, Brown AF, Mueller M, George P, Mosimann T, Flaws DF, Reiter M, Lamanna A, Haaf P, Pemberton CJ, Richards AM, Chu K, Reid CM, Peacock WF, Jaffe AS, Florkowski C, Deely JM, Than M. Validation of high-sensitivity troponin I in a 2-hour diagnostic strategy to assess 30-day outcomes in emergency department patients with possible acute coronary syndrome. J Am Coll Cardiol. 2013 Oct 1;62(14):1242-9. doi: 10.1016/j.jacc.2013.02.078.DOI: 10.1016/j.jacc.2013.02.078

Related calculators