Cardiac Power Output (CPO)
ورودیهای بالینی بیمار
حداقل ۳۰ — حداکثر ۲۰۰ • واحد: mmHg
حداقل ۱ — حداکثر ۱۵ • واحد: L/min
حداقل ۰ — حداکثر ۳۰ • واحد: mmHg
پارامترهای بالینی بیمار را در فرم روبرو وارد کنید و روی «محاسبه» کلیک نمایید تا نمره، طبقه خطر و اقدامات فوری نمایش داده شوند.
- Severe dysfunction0–0.6
- Moderately reduced0.6–1
- Normal to high1–6
The Cardiac Power Output (CPO) calculates calculating cardiac power output, the rate of energy output of the heart. Key inputs include mean arterial pressure. Scores guide initiating guideline-directed medical therapy, antithrombotic or anticoagulant regimens, or urgent coronary angiography. This standardized assessment improves clinical decision safety and bedside patient management.
Clinical Guidelines & Evidence
Calculates cardiac power output, the rate of energy output of the heart. Integrates both pressure and flow components of cardiac work. Strong hemodynamic predictor of mortality in cardiogenic shock.
Clinical Indication
The Cardiac Power Output (CPO) is indicated for bedside clinical practice to support Calculates cardiac power output, the rate of energy output of the heart. Integrates both pressure and flow components of cardiac work. Strong hemodynamic predictor of mortality in cardiogenic shock.. It assists healthcare providers in standardizing clinical assessment and therapeutic decision-making.
Target Population
Target population comprises Adult patients presenting with suspected or established coronary artery disease, cardiac arrhythmias, congestive heart failure, or valvular heart defects. Clinical application is indicated across Emergency department, cardiac care unit (CCU), cardiac catheterization laboratory, and outpatient cardiology clinics.
Limitations & Contraindications
In hemodynamically unstable cardiogenic shock, cardiac arrest, or refractory acute coronary syndromes, immediate resuscitation and coronary angiography supersede scoring.
Clinical Pearls & Action Plan
Continuous 12-lead ECG monitoring, serial cardiac troponin measurements, and echocardiographic evaluation align with ESC/ACC/AHA clinical practice guidelines.
Standard CPO = (MAP × CO) / 451. Original Tan formula: CPO-RAP = [(MAP - RAP) × CO] / 451. Where MAP = mean arterial pressure (mmHg), CO = cardiac output (L/min), RAP = right atrial pressure (mmHg), 451 = conversion constant
Input Parameters
| Name | Type | Required | Description |
|---|---|---|---|
| mean_arterial_pressure | float | Yes | Mean arterial pressure in mmHg(mmHg) |
| cardiac_output | float | Yes | Cardiac output in L/min(L/min) |
| right_atrial_pressure | float | No | Right atrial pressure in mmHg (optional, for original Tan formula)(mmHg) |
Score Interpretation & Guidance
| Range | Stage | Description |
|---|---|---|
| 0–0.6 | Severe dysfunction | Severe ventricular dysfunction |
| 0.6–1 | Moderately reduced | Moderately reduced cardiac power |
| 1–6 | Normal to high | Normal to high cardiac power |
Evidence-Based References (EBM)
- Tan LB. Cardiac pumping capability and prognosis in heart failure. Lancet. 1986 Dec 13;2(8520):1360-3. doi: 10.1016/s0140-6736(86)92002-6.DOI: 10.1016/s0140-6736(86)92002-6
- Fincke R, Hochman JS, Lowe AM, et al. Cardiac power is the strongest hemodynamic correlate of mortality in cardiogenic shock: a report from the SHOCK trial registry. J Am Coll Cardiol. 2004 Jul 21;44(2):340-8. doi: 10.1016/j.jacc.2004.03.060.DOI: 10.1016/j.jacc.2004.03.060
- Mendoza DD, Cooper HA, Panza JA. Cardiac power output predicts mortality across a broad spectrum of patients with acute cardiac disease. Am Heart J. 2007 Mar;153(3):366-70. doi: 10.1016/j.ahj.2006.11.014.DOI: 10.1016/j.ahj.2006.11.014
- Williams SG, Cooke GA, Wright DJ, et al. Peak exercise cardiac power output; a direct indicator of cardiac function strongly predictive of prognosis in chronic heart failure. Eur Heart J. 2001 Aug;22(16):1496-503. doi: 10.1053/euhj.2000.2547.DOI: 10.1053/euhj.2000.2547